Skip to main content
  • Description
  • Conversion tool for EGIS (Geodesic) averaged files to evoked potebtial .p file format.

  • Usage
  • EGIav2ep myEGIfile..egis myepfile myparfile.par

    with :

    • myEGIfile..egis: EGIS file to convert (with extension).
    • myepfile: output .ep file (no extension).
    • myparfile.par: text file containing conversion parameters (electrode names and numbers) (with extension).


  • Fields of parameter file and example
  • electrodes
    electrodes
    E128_E1.5851
    E128_E2.5852
    E128_E3.5853
    E128_E4.5854
    E128_E5.5855
    E128_E6.5856
    E128_E7.5857
    E128_E8.5858
    E128_E9.5859
    E128_E10.5860
    E128_E11.5861
    E128_E12.5862
    E128_E13.5863
    E128_E14.5864
    E128_E15.5865
    E128_E16.5866
    E128_E17.5867
    E128_E18.5868
    E128_E19.5869
    E128_E20.5870
    E128_E21.5871
    E128_E22.5872
    E128_E23.5873
    E128_E24.5874
    E128_E25.5875
    E128_E26.5876
    E128_E27.5877
    E128_E28.5878
    E128_E29.5879
    E128_E30.5880
    E128_E31.5881
    E128_E32.5882
    E128_E33.5883
    E128_E34.5884
    E128_E35.5885
    E128_E36.5886
    E128_E37.5887
    E128_E38.5888
    E128_E39.5889
    E128_E40.5890
    E128_E41.5891
    E128_E42.5892
    E128_E43.5893
    E128_E44.5894
    E128_E45.5895
    E128_E46.5896
    E128_E47.5897
    E128_E48.5898
    E128_E49.5899
    E128_E50.5900
    E128_E51.5901
    E128_E52.5902
    E128_E53.5903
    E128_E54.5904
    E128_E55.5905
    E128_E56.5906
    E128_E57.5907
    E128_E58.5908
    E128_E59.5909
    E128_E60.5910
    E128_E61.5911
    E128_E62.5912
    E128_E63.5913
    E128_E64.5914
    E128_E65.5915
    E128_E66.5916
    E128_E67.5917
    E128_E68.5918
    E128_E69.5919
    E128_E70.5920
    E128_E71.5921
    E128_E72.5922
    E128_E73.5923
    E128_E74.5924
    E128_E75.5925
    E128_E76.5926
    E128_E77.5927
    E128_E78.5928
    E128_E79.5929
    E128_E80.5930
    E128_E81.5931
    E128_E82.5932
    E128_E83.5933
    E128_E84.5934
    E128_E85.5935
    E128_E86.5936
    E128_E87.5937
    E128_E88.5938
    E128_E89.5939
    E128_E90.5940
    E128_E91.5941
    E128_E92.5942
    E128_E93.5943
    E128_E94.5944
    E128_E95.5945
    E128_E96.5946
    E128_E97.5947
    E128_E98.5948
    E128_E99.5949
    E128_E100.5950
    E128_E101.5951
    E128_E102.5952
    E128_E103.5953
    E128_E104.5954
    E128_E105.5955
    E128_E106.5956
    E128_E107.5957
    E128_E108.5958
    E128_E109.5959
    E128_E110.5960
    E128_E111.5961
    E128_E112.5962
    E128_E113.5963
    E128_E114.5964
    E128_E115.5965
    E128_E116.5966
    E128_E117.5967
    E128_E118.5968
    E128_E119.5969
    E128_E120.5970
    E128_E121.5971
    E128_E122.5972
    E128_E123.5973
    E128_E124.5974
    E128_E125.5975
    E128_E126.5976
    E128_E127.5977
    E128_E128.5978

    Output channel name list :

    Names and numbers corresponding to elec.dat definition for converted channels, or name and -1 if the channel is not defined in elec.dat.

    The order should be the same as in the input EGIS file.


  • Example
  • Conversion from EGIS with GSN HydroCell 128 channels :
    EGIav2ep "my-file-to-convert..egis" myoutput-file conv-GSN-128.par
    Read and convert my-file-to-convert..egis to myoutput-file.p with electrodes defined for GSN HydroCell 128 channels. The parameter file is available to download here : conv-GSN-128.par
    Please ask if you are using another electrode configuration.

  • Comments

  • Current version
  • 1.00 18-12-2012

  • History
    • 1.00 18-12-2012 (PEA) : 1st version.


  • Files
  • $ELANPATH/bin/EGIav2ep

  • See also
  • EGIraw2eeg

AttachmentSize
conv-GSN-128.par1.78 KB